On 11/14/2017 09:52 AM, Grzegorz Bakalarski wrote: > I have a server (R815) with PERC H710. I have 4 disks and RAID-5 on them. The > server have 2 empty disk slots. > > After night I noticed 2 disks got predicted failure state - LEDs on disk > flash yellow (not green) on them (2 of them). MegaCLI shows that 2 disks have > high "Predictive Failure Count:" - some few thousands. GB,
*IF* this all rebuilds fine and goes Optimal again, you really want to: megacli fwtermlog dsply aall | grep -i punct If you see a punctured block, you're gonna have to back off what you can, rebuild the RAID from scratch and restore, because there's no good way to fix a punctured stripe. (ignore the lines that say the controller supports puncturing). If you have to rebuild, i'd go RAID6 with your 6 drives. --stephen -- Stephen Dowdy - Systems Administrator - NCAR/RAL 303.497.2869 - [email protected] - http://www.ral.ucar.edu/~sdowdy/ _______________________________________________ Linux-PowerEdge mailing list [email protected] https://lists.us.dell.com/mailman/listinfo/linux-poweredge