with just updated dsu to ver 1.5.1 I still see only 1 NIC(four ports) out of 3(12 ports in total)

$ dsu --inventory --log-level=4 --output-log-file=dsu.log/log
DELL EMC System Update 1.5.1
Copyright (C) 2014 DELL EMC Proprietary.
Verifying catalog installation ...
Installing catalog from repository ...
Fetching dsucatalog ...
Reading the catalog ...
Verifying inventory collector installation ...
Getting System Inventory ...
warning: Inventory collector returned with partial failure.

1. OpenManage Server Administrator  ( Version : 8.5.0 )
....

And in the log:

$ tailf dsu.log/log
#ID : cda44105-3441-4637-991e-156749142b90
#DSU Version: 1.5.1 - cda44105-3441-4637-991e-156749142b90
#System IP: 252.127.0.0 - cda44105-3441-4637-991e-156749142b90
#Date: 22-11-2017 11:48:58 - cda44105-3441-4637-991e-156749142b90 #Fields:          ID                       |        Date Time     | Level    |         Message     cda44105-3441-4637-991e-156749142b90  |    22-11-2017 11:48:58 |    INFO    |    Verifying catalog installation ...     cda44105-3441-4637-991e-156749142b90  |    22-11-2017 11:49:06 |    INFO    |    Installing catalog from repository ...     cda44105-3441-4637-991e-156749142b90  |    22-11-2017 11:49:15 |    INFO    |    Fetching dsucatalog ...     cda44105-3441-4637-991e-156749142b90  |    22-11-2017 11:49:25 |    INFO    |    Reading the catalog ...     cda44105-3441-4637-991e-156749142b90  |    22-11-2017 11:49:33 |    INFO    |    Verifying inventory collector installation ...     cda44105-3441-4637-991e-156749142b90  |    22-11-2017 11:49:33 |    INFO    |    Getting System Inventory ...     cda44105-3441-4637-991e-156749142b90  |    22-11-2017 12:12:41 |    WARNING    |    warning: Inventory collector returned with partial failure.     cda44105-3441-4637-991e-156749142b90  |    22-11-2017 12:12:42 |    INFO    |    Exiting DSU!


What might be wrong? Most importantly - Would you know when it might get fixed?

regards, L.


On 30/10/17 15:51, [email protected] wrote:
Dell - Internal Use - Confidential


The segmentation fault issue is not related to NIC report issue. We are 
checking with internal team about the NIC inventory issue.



Thanks

Santosh

-----Original Message-----
From: linux-poweredge-bounces-Lists On Behalf Of lejeczek
Sent: Monday, October 30, 2017 9:04 PM
To: Gore, Santosh <[email protected]>; linux-poweredge-Lists 
<[email protected]>
Subject: Re: [Linux-PowerEdge] dsu segfaults



hi Santhos



would it be right to assume that the segfaults have something to do or are 
direct cause for dsu on my r815 to see/report only one NIC out of three?



regards, L.



On 30/10/17 04:55, [email protected]<mailto:[email protected]> wrote:

Dell - Internal Use - Confidential
Hi
Thanks for providing the information. This issue is fixed and will be available 
in the next DSU release.
Thanks
Santosh
-----Original Message-----
From: linux-poweredge-bounces-Lists On Behalf Of lejeczek
Sent: Friday, October 27, 2017 6:52 PM
To: linux-poweredge-Lists 
<[email protected]<mailto:[email protected]>>
Subject: [Linux-PowerEdge] dsu segfaults
@dell developers
during dsu operation, like here:
$ dsu -u --log-level=4
DELL EMC System Update 1.5.0
Copyright (C) 2014 DELL EMC Proprietary.
Verifying catalog installation ...
Installing catalog from repository ...
Fetching dsucatalog ...
Reading the catalog ...
Verifying inventory collector installation ...
Getting System Inventory ...
warning: Inventory collector returned with partial failure.
Determining Applicable Updates ...
No Applicable Updates Available
Exiting DSU!
$ echo $?
R815, OS, Centos 7.4 reports:
....
[Fri Oct 27 14:17:24 2017] sasdupie[114626]: segfault at
7ffb9440c5b0 ip 00007f06627f6f5b sp 00007ffc12009f98 error 4 in 
libc-2.17.so[7f06626c0000+1b8000] [Fri Oct 27 14:18:11 2017] traps: 
MarvCtrlIE[116522] general protection ip:7f9c4546338b sp:7ffd6583fe50 error:0 
in libc-2.17.so[7f9c453f8000+1b8000] ...
regards, L.
_______________________________________________
Linux-PowerEdge mailing list
[email protected]<mailto:[email protected]>
https://lists.us.dell.com/mailman/listinfo/linux-poweredge


_______________________________________________

Linux-PowerEdge mailing list

[email protected]<mailto:[email protected]>

https://lists.us.dell.com/mailman/listinfo/linux-poweredge

_______________________________________________
Linux-PowerEdge mailing list
[email protected]
https://lists.us.dell.com/mailman/listinfo/linux-poweredge

Reply via email to