Hi Folks, I have a customer seeing incorrect date/time stamps when running "omreport system esmlog". Even clearing the logs does not help. ( see example below)
This problem is occurring on R630s running OMSA 9.1.0 & DRAC FW 2.50.50.50, 2.40.40.40. Is this a known bug ? What is the recommended fix? Appreciate the help! *********************************************************************************************************** For example: ================================== Severity : Critical Date and Time : Tue Jun 5 21:51:54 2153 Description : The power input for power supply 1 is lost. Severity : Ok Date and Time : Wed Jun 6 10:33:22 2153 Description : The input power for power supply 1 has been restored. Severity : Ok Date and Time : Wed Jun 6 10:33:26 2153 Description : The power supplies are redundant. Severity : Critical Date and Time : Wed Aug 1 10:14:07 2153 Description : The chassis is open while the power is off. Severity : Ok Date and Time : Wed Aug 1 10:14:12 2153 Description : The chassis is closed while the power is off. Severity : Critical Date and Time : Tue Mar 12 10:21:55 2154 Description : The chassis is open while the power is off. Severity : Ok Date and Time : Tue Mar 12 10:22:00 2154 Description : The chassis is closed while the power is off. =================================== The output of [racadm getsel] on the DRAC is =================================== Record: 29 Date/Time: 04/29/2017 15:23:38 Source: system Severity: Critical Description: The power input for power supply 1 is lost. ------------------------------------------------------------------------------- Record: 30 Date/Time: 04/30/2017 04:05:06 Source: system Severity: Ok Description: The input power for power supply 1 has been restored. ------------------------------------------------------------------------------- Record: 31 Date/Time: 04/30/2017 04:05:10 Source: system Severity: Ok Description: The power supplies are redundant. ------------------------------------------------------------------------------- Record: 32 Date/Time: 06/25/2017 03:45:51 Source: system Severity: Critical Description: The chassis is open while the power is off. ------------------------------------------------------------------------------- Record: 33 Date/Time: 06/25/2017 03:45:56 Source: system Severity: Ok Description: The chassis is closed while the power is off. ------------------------------------------------------------------------------- Record: 34 Date/Time: 02/03/2018 03:53:39 Source: system Severity: Critical Description: The chassis is open while the power is off. ------------------------------------------------------------------------------- Record: 35 Date/Time: 02/03/2018 03:53:44 Source: system Severity: Ok Description: The chassis is closed while the power is off. ------------------------------------------------------------------------------- ===================================== The output of [ipmitool sel list] matches the DRAC output. Shalin Patel Enterprise Solutions Consultant Dell EMC | Enterprise Solutions Group - NYC [email protected]<mailto:[email protected]> Mobile: 347-556-8563 ¢ Learn about Dell Storage<http://www.dellstorage.com/>. ¢ Understand the environment - DPACK.<http://www.dell.com/learn/us/en/04/campaigns/dell-performance-analysis-collection-kit-dpack>
_______________________________________________ Linux-PowerEdge mailing list [email protected] https://lists.us.dell.com/mailman/listinfo/linux-poweredge