Sorry for typo in below email…. The CPLD and Power Supply firmware packages are NOT included in the default catalog
From: linux-poweredge-bounces-Lists <[email protected]> On Behalf Of Gore, Santosh Sent: Wednesday, February 26, 2020 1:45 PM To: [email protected]; linux-poweredge-Lists Subject: Re: [Linux-PowerEdge] Latest DSU - Not updating CPLD or PS firmware. Hi The CPLD and Power Supply firmware packages are NOT included in the default catalog. If you want to update the PowerSupply and CPLD then create a repository with DellEMC Repository Manager ( DRM) tool by importing PowerSupply and CPLD components in repository. Then use exported repository to update CPLD and PowerSupply components using DSU. The information and download of DRM is available in link - https://www.dell.com/support/article/us/en/04/sln283183/support-for-dell-emc-repository-manager-drm?lang=en#download Thanks Santosh From: linux-poweredge-bounces-Lists <[email protected]<mailto:[email protected]>> On Behalf Of Nathanial Marsh Sent: Wednesday, February 26, 2020 1:35 PM To: linux-poweredge-Lists Subject: [Linux-PowerEdge] Latest DSU - Not updating CPLD or PS firmware. [EXTERNAL EMAIL] Hi All We have been using a Linux Live OS with some Ansible magic for quite some time now to update our servers except it has recently come to my attention that DSU is not updating CPLD or PS FW's. These show in when running the inventory check but don't show when running DSU to update. See below: [root@DSU ~]# dsu -i --source-type=REPOSITORY --source-location="ftp.dell.com/catalog<http://ftp.dell.com/catalog>" DELL EMC System Update 1.7.0 Copyright (C) 2014 DELL EMC Proprietary. Verifying catalog installation ... Fetching Catalog ... Extracting /usr/libexec/dell_dup/Catalog.gz Reading the catalog ... Verifying inventory collector installation ... Trying to connect using https Fetching invcol_HW0HN_LN64_20_02_00_771_A00.sign ... Getting System Inventory ... warning: Inventory collector returned with partial failure. 1. Application, OpenManage Server Administrator ( Version : 9.4.0 ) 2. BIOS, BIOS ( Version : 2.4.8 ) 3. Application, Lifecycle Controller ( Version : 4.00.00.00 ) 4. Application, Dell 64 Bit uEFI Diagnostics, version 4301, 4301A38, 4301.39 ( Version : 4301A38 ) 5. Firmware, Integrated Dell Remote Access Controller ( Version : 4.00.00.00 ) 6. Application, OS COLLECTOR, 5.0, A00 ( Version : 5.0 ) 7. Application, iDRAC Service Module Embedded Package, v3.4.0, A00 ( Version : 3.4.0 ) 8. Firmware, System CPLD ( Version : 1.1.3 ) 9. Firmware, Power Supply ( Version : 00.11.3F ) 10. Firmware, Power Supply ( Version : 00.11.3F ) 11. Firmware, PERC H740P Mini Controller 0 Firmware ( Version : 50.9.3-2949 ) 12. Firmware, Backplane Expander FW ( Version : 2.46 ) 13. Firmware, NetXtreme BCM5720 2-port Gigabit Ethernet PCIe (em1) ( Version : 21.40.21 ) 14. Firmware, NetXtreme BCM5720 2-port Gigabit Ethernet PCIe (em2) ( Version : 21.40.21 ) 15. Firmware, NetXtreme BCM5720 2-port Gigabit Ethernet PCIe (em4) ( Version : 21.40.21 ) 16. Firmware, NetXtreme BCM5720 2-port Gigabit Ethernet PCIe (em3) ( Version : 21.40.21 ) 17. Application, Inventory Collector ( Version : 20.02.00 ) Now trying to run an update: [root@DSU ~]# dsu --source-type=REPOSITORY --source-location="ftp.dell.com/catalog<http://ftp.dell.com/catalog>" DELL EMC System Update 1.7.0 Copyright (C) 2014 DELL EMC Proprietary. Verifying catalog installation ... Fetching Catalog ... Extracting /usr/libexec/dell_dup/Catalog.gz Reading the catalog ... Verifying inventory collector installation ... Trying to connect using https Fetching invcol_HW0HN_LN64_20_02_00_771_A00.sign ... Getting System Inventory ... warning: Inventory collector returned with partial failure. Determining Applicable Updates ... |--------DELL EMC System Update-----------| [ ] represents 'not selected' [*] represents 'selected' [-] represents 'Component already at repository version (can be selected only if -e option is used)' Choose: q - Quit without update, c to Commit, <number> - To Select/Deselect, a - Select All, n - Select None [-]1 BIOS Current Version : 2.4.8 Same as : 2.4.8, Criticality : Urgent, Type : BIOS [-]2 Dell 64 Bit uEFI Diagnostics, version 4301, 4301A38, 4301.39 Current Version : 4301A38 Same as : 4301A38, Criticality : Optional, Type : Application [-]3 PERC H740P Mini Controller 0 Firmware Current Version : 50.9.3-2949 Same as : 50.9.3-2949, Criticality : Urgent, Type : Firmware [-]4 Backplane Expander FW Current Version : 2.46 Same as : 2.46, Criticality : Recommended, Type : Firmware [-]5 Integrated Dell Remote Access Controller Current Version : 4.00.00.00 Same as : 4.00.00.00, Criticality : Recommended, Type : Firmware [-]6 NetXtreme BCM5720 2-port Gigabit Ethernet PCIe (em3) Current Version : 21.40.21 Same as : 21.40.21, Criticality : Recommended, Type : Firmware [-]7 NetXtreme BCM5720 2-port Gigabit Ethernet PCIe (em4) Current Version : 21.40.21 Same as : 21.40.21, Criticality : Recommended, Type : Firmware [-]8 NetXtreme BCM5720 2-port Gigabit Ethernet PCIe (em2) Current Version : 21.40.21 Same as : 21.40.21, Criticality : Recommended, Type : Firmware [-]9 NetXtreme BCM5720 2-port Gigabit Ethernet PCIe (em1) Current Version : 21.40.21 Same as : 21.40.21, Criticality : Recommended, Type : Firmware [-]10 iDRAC Service Module Embedded Package, v3.4.0, A00 Current Version : 3.4.0 Same as : 3.4.0, Criticality : Optional, Type : Application [-]11 OS COLLECTOR, 5.0, A00 Current Version : 5.0 Same as : 5.0, Criticality : Optional, Type : Application Enter your choice : Any idea's on why this might be the case? Thanks in advance
_______________________________________________ Linux-PowerEdge mailing list [email protected] https://lists.us.dell.com/mailman/listinfo/linux-poweredge