Hey Frank, This problem gets dicussed on the list every few months. Here's my troubleshooting steps. http://lists.us.dell.com/pipermail/linux-poweredge/2008-October/037637.h tml
Doesn't always works, usually does the trick for me though. Patrick > -----Original Message----- > From: [email protected] > [mailto:[email protected]] On Behalf > Of Frank Collette IV > Sent: Friday, July 17, 2009 9:04 AM > To: [email protected] > Subject: Re: omreport not displaying information > > Unfortunately, didn't resolve the issue. > > > [r...@jxnms001 ~]# /opt/dell/srvadmin/hapi/bin/dsm_sa_ipmi start > Starting dsm_sa_ipmi drivers: > > [ OK ] > > > [r...@jxnms001 ~]# srvadmin-services.sh status > dell_rbu (module) is stopped > ipmi driver is stopped > dsm_sa_datamgr32d is stopped > dsm_sa_eventmgr32d is stopped > dsm_sa_snmp32d is stopped > > dsm_om_shrsvc32d (pid 18874) is running > dsm_om_connsvc32d (pid 18938 18937) is running > > [r...@jxnms001 ~]# srvadmin-services.sh restart > > > Shutting down DSM SA Shared Services: > [ OK ] > > > Shutting down DSM SA Connection Service: > [ OK ] > > > Starting mptctl: > Waiting for mptctl driver registration to complete: > > > > > [ OK ] > > Starting Systems Management Device Drivers: > Starting dell_rbu: > [ OK ] > Starting ipmi driver: > [ OK ] > Starting Systems Management Device Drivers: > Starting dell_rbu: Already started > [ OK ] > Starting ipmi driver: > [ OK ] > Starting Systems Management Data Engine: > Starting dsm_sa_datamgr32d: > [ OK ] > Starting dsm_sa_eventmgr32d: > [ OK ] > Starting dsm_sa_snmp32d: > [ OK ] > Starting DSM SA Shared Services: > [ OK ] > > Starting DSM SA Connection Service: > [ OK ] > > [r...@jxnms001 ~]# srvadmin-services.sh status > > dell_rbu (module) is running > ipmi driver is stopped > > dsm_sa_datamgr32d (pid 20901) is running > dsm_sa_eventmgr32d is stopped > dsm_sa_snmp32d is stopped > dsm_om_shrsvc32d (pid 20971) is running > dsm_om_connsvc32d (pid 21035 21034) is running > [r...@jxnms001 ~]# > > > > On Thu, Jul 16, 2009 at 3:23 PM, Chase Bolt > <[email protected]> wrote: > > > Try running these two commands and see if it fixes it. > > # /opt/dell/srvadmin/hapi/bin/dsm_sa_ipmi start > # srvadmin-services.sh restart > > > Frank Collette IV wrote: > > Output that would be requested is displayed below. > > > > [r...@jxnms001 bin]# srvadmin-services.sh status > dell_rbu (module) is running > ipmi driver is stopped > dsm_sa_datamgr32d (pid 19839) is running > dsm_sa_eventmgr32d (pid 19893) is running > dsm_sa_snmp32d (pid 19917 19916) is running > dsm_om_shrsvc32d (pid 18874) is running > dsm_om_connsvc32d (pid 18938 18937) is running > [r...@jxnms001 bin]# > > > Output of what srvadmin versions I'm running: > > > > [r...@jxnms001 bin]# rpm -qa |grep srvadmin > srvadmin-omilcore-6.1.0-648 > srvadmin-racadm4-6.1.0-648 > srvadmin-rac4-6.1.0-648 > srvadmin-webserver-6.1.0-648 > srvadmin-omacore-6.1.0-648 > srvadmin-omauth-6.1.0-648.rhel5 > srvadmin-racadm5-6.1.0-648 > srvadmin-rac5-6.1.0-648 > srvadmin-omcommon-6.1.0-648 > srvadmin-isvc-6.1.0-648 > srvadmin-rac4-components-6.1.0-648 > srvadmin-base-6.1.0-648 > srvadmin-racdrsc5-6.1.0-648 > srvadmin-wsmanclient-6.1.0-648.rhel5 > srvadmin-idracdrsc-6.1.0-648 > srvadmin-ssa-6.1.0-648.rhel5 > srvadmin-syscheck-6.1.0-648 > srvadmin-omhip-6.1.0-648 > srvadmin-cm-6.1.0-648 > srvadmin-racdrsc4-6.1.0-648 > srvadmin-storage-6.1.0-648 > srvadmin-iws-6.1.0-648 > srvadmin-idracadm-6.1.0-648 > srvadmin-standardAgent-6.1.0-648 > srvadmin-deng-6.1.0-648 > srvadmin-jre-6.1.0-648 > srvadmin-storageservices-6.1.0-648 > srvadmin-idrac-6.1.0-648 > srvadmin-all-6.1.0-648 > srvadmin-hapi-6.1.0-648 > srvadmin-racsvc-6.1.0-648 > srvadmin-rac5-components-6.1.0-648 > srvadmin-idrac-components-6.1.0-648 > [r...@jxnms001 bin]# > > > Now, output of my omreport commands: > > > > [r...@jxnms001 bin]# omreport chassis > Health > > For further help, type the command > followed by -? > > [r...@jxnms001 bin]# omreport storage vdisk > List of Virtual Disks on Controller (Slot ) > > [r...@jxnms001 bin]# omreport storage > pdisk controller=0 > Invalid controller value. Read, controller=0 > No controllers found. > > [r...@jxnms001 bin]# > > > Anyone with any idea of what might be happening > here, please let me know. I have not rebooted the server, > but wouldn't think I would need to either. omreport chassis > did work 1 time, but afterwards all services stopped, very strange. > > Thanks for any help provided! > > --Frank > > > ________________________________ > > > _______________________________________________ > Linux-PowerEdge mailing list > [email protected] > > https://lists.us.dell.com/mailman/listinfo/linux-poweredge > Please read the FAQ at http://lists.us.dell.com/faq > > > _______________________________________________ Linux-PowerEdge mailing list [email protected] https://lists.us.dell.com/mailman/listinfo/linux-poweredge Please read the FAQ at http://lists.us.dell.com/faq