Is it just to type: dkms install? Or what ist he correct command?
 
Von: [email protected] [mailto:[email protected]] 
Gesendet: Donnerstag, 27. August 2009 15:54
An: [email protected]; [email protected]
Betreff: RE: driver update problem
 
Dkms doesn't install storage drivers by default. You need to explicitly run
the dkms install command to add them to the initrd.
 
From: [email protected]
[mailto:[email protected]] On Behalf Of Rene
Rosenberger
Sent: Thursday, August 27, 2009 8:43 AM
To: linux-poweredge-Lists
Subject: driver update problem
 
Hi,
 
does anyone know why the new driver isnt loaded after a system restart?
 
xxxxxxxx:~ # dkms status
megaraid_sas, v00.00.03.21: added
 
xxxxxxxx:~ # modinfo megaraid-sas
filename:
/lib/modules/2.6.25.5-1.1-default/kernel/drivers/scsi/megaraid/megaraid_sas.
ko
description:    LSI MegaRAID SAS Driver
author:         [email protected]
version:        00.00.03.16-rc1
license:        GPL
srcversion:     7B4E044729438F1BDAA27CB
alias:          pci:v00001028d00000015sv*sd*bc*sc*i*
alias:          pci:v00001000d00000413sv*sd*bc*sc*i*
alias:          pci:v00001000d00000060sv*sd*bc*sc*i*
alias:          pci:v00001000d00000411sv*sd*bc*sc*i*
depends:        scsi_mod
supported:      yes
vermagic:       2.6.25.5-1.1-default SMP mod_unload
parm:           poll_mode_io:Complete cmds from IO path, (default=0) (int)
 
regards,
 
Rene 
 
_______________________________________________
Linux-PowerEdge mailing list
[email protected]
https://lists.us.dell.com/mailman/listinfo/linux-poweredge
Please read the FAQ at http://lists.us.dell.com/faq