Joe Janitor wrote:

> Dell Poweredge 2450 running RH6.2, PERC2 hardware raid
> controller - RAID1 configuration.

Someone who has a PERC2 controller can probably answer this better than I
can.

You're using hardware RAID, which is implemented at the driver and/or
hardware level.  The md code in the kernel is not involved, thus the lack of
information from /proc/mdstat.

Check to see if the PERC2 driver adds an entry in the /proc filesystem that
can give you some clue as to the status of the controller.  We use
ICP-Vortex cards, and they provide an entries in /proc/scsi/gdth that give
detailed info on the status of the card and the devices attached.

--
  /-Charles R. (C. R.) Oldham   | NCA Commission on Schools  -\
 [EMAIL PROTECTED]              |  Arizona State University  _-\
/-V:602/965-8700 F:602/965-9423 |             Tempe, AZ USA X_>-\


-
To unsubscribe from this list: send the line "unsubscribe linux-raid" in
the body of a message to [EMAIL PROTECTED]