Joe Janitor wrote:
> Dell Poweredge 2450 running RH6.2, PERC2 hardware raid
> controller - RAID1 configuration.
Someone who has a PERC2 controller can probably answer this better than I
can.
You're using hardware RAID, which is implemented at the driver and/or
hardware level. The md code in the kernel is not involved, thus the lack of
information from /proc/mdstat.
Check to see if the PERC2 driver adds an entry in the /proc filesystem that
can give you some clue as to the status of the controller. We use
ICP-Vortex cards, and they provide an entries in /proc/scsi/gdth that give
detailed info on the status of the card and the devices attached.
--
/-Charles R. (C. R.) Oldham | NCA Commission on Schools -\
[EMAIL PROTECTED] | Arizona State University _-\
/-V:602/965-8700 F:602/965-9423 | Tempe, AZ USA X_>-\
-
To unsubscribe from this list: send the line "unsubscribe linux-raid" in