Hello, I've set up my DAC960 with 5 Seagate Elite disks, and 5 Seagate 
Barracudas. Now I always get a problem with "Physical Drive 0". Here is the 
setup:

Mylex DAC960pg 3-channel, Barracudas connected to Channel 2 
internally.Errors:

DAC960#0: Physical Drive 2:1 Error Log: Sense key = 6, ASC = 29, ASCQ = 
02 (and Information = 00000000 00000000 on the next line). This message it 
repeats from all drives 2:1 to 2:4. Then comes 2:0 :

DAC960#0: Physical Drive 2:0 killed because of bad tag returned from drive
DAC960#0: Physical Drive 2:0 is now DEAD
DAC960#0: Logical Drive 1 (/dev/rd/c0d1) is now CRITICAL.

This happened last week too, but then I didn't even manage to mke2fs it, which 
went smoothly this time. These errors occured while copying data onto the 
disk. I don't think the disk is broken, because I switched SCSI ID with another 
drive, and set up the controller again, and it still gives error on 2:0 though it's 
another disk.

I'm running Mandrake 6.0 with 2.2.7 kernel and the "official" 2.2.2 patch for it.

Any help deeply appreciated, I'm THAT close to finishing this server (1 week 
overdue)...

Kent R. Nilsen
[EMAIL PROTECTED]

Reply via email to