I had to disable it in the BIOS of the DAC960 (before booting). Maybe it can be
done by software, but then you'd have to check the documentation (don't think I
found anything about it there)
Kent
> I have a DAC960PG driving 6 9Gbyte Seagate Barracudas in an internal
> SCA hot swap cabinet. One of the drive sin the array consistently
> keeps going off-lkine with the 'bad tag' received message. I think
> that I have rebuilt the array about a dozen times in the last few
> days.
>
> Did you disable tagged queueing globally in the driver sources or is
> there a knob in /proc/rd that I haven't found yet? If I can do this
> selectively I would like to for the offending drive.
>
> > Kent R. Nilsen
>
> Thanks much for any information that you would like to share. Have a
> pleasant remainder of the week.
>
> Greg
>
> }-- End of excerpt from [EMAIL PROTECTED]
>
> As always,
> Dr. G.W. Wettstein Enjellic Systems Development - Specializing
> 4206 N. 19th Ave. in information infra-structure solutions.
> Fargo, ND 58102 WWW: http://www.enjellic.com Phone:
> 701-281-1686 EMAIL: [EMAIL PROTECTED]
> --------------------------------------------------------------------------
> ---- "Why would you WANT to port C news to your PC? Wouldn't it be
> smarter and about as cost-effective to port your PC to the trashcan and
> buy a real computer that runs a real operating system like UNIX?"
> -- Brian Kantor