hello,
i have a little question,
i made a mirror of a lokal 'disk' over nbd (net block device) to a
second server.
if the first server goes down (failed) the second server mounts the
mirrored 'disk' localy (after fsck) and starts the service (e.g.
mailservice, samba homedirs..) ..
everything works fine, but:
now the primary server comes up again (after repair)
the secondary server stops all services, unmounts the 'disk' and exports
it again over nbd
but how could i tell the md driver on the primary server that the local
disk is faulty and the 'nbd-disk' from the second server is ok
thank you
greetings from vienna
leo