On Mon, 14 Feb 2000, Peter Pregler wrote:
> All is fine but during reconstruction I get a few syslog-messages that I
> simply cannot believe are true. The message in question are:
>
> Feb 12 11:31:52 kludge kernel: md: serializing resync, md8 has overlapping
> physical units with md9!
Just means both md partitions have component partitions on the same drive
- isn't this in the faq, Jakob? They have to be serialized because the
bandwidth for sync is rather limited and it'd be thrashing to let the
resync go by in parallel.
Cheers,
--
_/\ Christian Reis is sometimes [EMAIL PROTECTED]
\/~ suicide architect | free software advocate | mountain biker