On Tue, Jun 20, 2000 at 05:21:15PM -0400, Richard Bollinger wrote:
> The message about overlaping physical units does not indicate failure...
>
> Where there are multiple mirrors on the same physical disks, the Raid code
> avoids recovering more than one at a time for performance reasons. It
> should recover the first one selected, then sequentially the other mirrors
> in turn until complete. Hopefully you have seen this progress in
> /dev/mdstat .
I think you mean /proc/mdstat
Phil
--
Philip Edelbrock -- IS Manager -- Edge Design, Corvallis, OR
[EMAIL PROTECTED] -- http://www.netroedge.com/~phil
PGP F16: 01 D2 FD 01 B5 46 F4 F0 3A 8B 9D 7E 14 7F FB 7A