Hi,

I modified the perftest program ib_read_bw to use sge lists. The length of each 
sge is 1 (one) byte. I configured the QP to support up to 32 sges (aligned with 
the capabilities of the device).

Now, everything works correct up to 30 sges. Using 31 or 32 sges, I receive 29 
bytes in both cases, but completion gives local length error.

I am running on CentOS 5.3, Intel E5540, OFED 1.4.1, and ConnectX w/fw 2.6.000.



Thanks, Håkon

--
Håkon Bugge
[email protected]
+47 924 84 514



--
To unsubscribe from this list: send the line "unsubscribe linux-rdma" in
the body of a message to [email protected]
More majordomo info at  http://vger.kernel.org/majordomo-info.html