> I am told that the customer has modified the SRP code, which is why I cannot 
 > go by the ib_srp.c code. 

Can you not ask the customer??  Or if you have the object code, look for
calls to srq functions in the binary??

  > 1. Would the Syndrome field show CC INVALID if SRQ were being used?
  > If so, in which IB message would it show---RDMA read response, or in
  > an initial RC SEND message or both?

As I said before, the implication is only one way.  If end-to-end flow
control is not used, that does not imply anything -- the CM protocol
allows flow control to be turned off even if an SRQ is not used.

 - R.
-- 
Roland Dreier <[email protected]> || For corporate legal information go to:
http://www.cisco.com/web/about/doing_business/legal/cri/index.html
--
To unsubscribe from this list: send the line "unsubscribe linux-rdma" in
the body of a message to [email protected]
More majordomo info at  http://vger.kernel.org/majordomo-info.html