On Mon, 2 Oct 2023 at 18:58, Manivannan Sadhasivam <[email protected]> wrote: > > On Mon, Oct 02, 2023 at 06:00:37PM +0300, Dmitry Baryshkov wrote: > > On Mon, 2 Oct 2023 at 17:52, Manivannan Sadhasivam <[email protected]> wrote: > > > > > > On Sun, Oct 01, 2023 at 06:26:14PM +0100, Caleb Connolly wrote: > > > > > > > > > > > > On 01/10/2023 16:57, Manivannan Sadhasivam wrote: > > > > > On Fri, Sep 29, 2023 at 05:16:16PM +0100, Caleb Connolly wrote: > > > > > > The Thermal Mitigation Device (TMD) Service is a QMI service that > > > > > > runs > > > > > > on remote subsystems (the modem and DSPs) on Qualcomm SoCs. > > > > > > It exposes various mitigations including passive thermal controls > > > > > > and > > > > > > rail voltage restrictions. > > > > > > > > > > > > This series introduces support for exposing TMDs as cooling devices > > > > > > in the kernel through the thermal framework, using the QMI > > > > > > interface. > > > > > > > > > > > > Each TMD client is described as a child of the remoteproc node in > > > > > > devicetree. With subnodes for each control. > > > > > > > > > > > > > > > > Daniel expressed concerns in the past aganist representing TMD driver > > > > > as a > > > > > cooling device since it is not tied to thermal zones and the > > > > > governors cannot > > > > > use it. Instead he suggested to represent it as a powercap device > > > > > with thermal > > > > > constraints. > > > > > > > > Hi Mani, > > > > > > > > Forgive me as I'm not yet super familiar with the thermal subsystem. > > > > > > > > As I understand it, the DT layout here enables each control to be > > > > referenced > > > > under the thermal zones, at least this is the approach taken in CAF 4.9. > > > > > > > > Maybe I don't quite understand what you mean, are you saying that using > > > > thermal zones is the wrong approach? > > > > > > Thermal framework expects each thermal zone represented in DT to have > > > atleast > > > one corresponding thermal sensor defined using "thermal-sensors" > > > property. But > > > with TMD, there is no thermal sensor AFAIK. > > > > As far as I understand, no. It is perfectly fine to have 'cooling' > > devices, which react to external thermal monitoring events. I might be > > mistaken, but I think that is the case here, isn't it? > > > > Yes it is represented as cooling device(s). But I do not see any cognizant way > to plug it with thermal zones i.e., unless TMD itself reports temperature of > the > modem, using it as a cooling device for external temperature events doesn't > sound good to me.
Why? We have compute, q6, wlan tsens sensors. So it seems natural to tell CDSP to slow down if compute sensor reports overheating. > > - Mani > > > > > > > > > > > > > > So please look into that approach. > > > > > > > > Any recommended reading? Or drivers I can use as a reference? > > > > > > > > > > drivers/powercap/arm_scmi_powercap.c seems to be a good reference. > > > > > > - Mani > > > > > > > Thanks > > > > > > > > > > - Mani > > > > > > > > > > > This series is based on previous work by Bhupesh Sharma which can be > > > > > > found at [1]. I'm sending this as a fresh series as it has been a > > > > > > year since the original version and I have rewritten most of the > > > > > > driver. > > > > > > > > > > > > [1]: > > > > > > https://lore.kernel.org/linux-arm-msm/[email protected]/ > > > > > > > > > > > > --- > > > > > > Caleb Connolly (4): > > > > > > remoteproc: qcom: probe all child devices > > > > > > dt-bindings: thermal: Add qcom,qmi-cooling yaml bindings > > > > > > thermal: qcom: add qmi-cooling driver > > > > > > MAINTAINERS: Add entry for Qualcomm Cooling Driver > > > > > > > > > > > > .../bindings/remoteproc/qcom,msm8996-mss-pil.yaml | 13 + > > > > > > .../bindings/remoteproc/qcom,pas-common.yaml | 6 + > > > > > > .../bindings/thermal/qcom,qmi-cooling.yaml | 168 +++++++ > > > > > > MAINTAINERS | 8 + > > > > > > drivers/remoteproc/qcom_q6v5.c | 4 + > > > > > > drivers/remoteproc/qcom_q6v5_mss.c | 8 - > > > > > > drivers/thermal/qcom/Kconfig | 13 + > > > > > > drivers/thermal/qcom/Makefile | 1 + > > > > > > drivers/thermal/qcom/qmi-cooling.c | 520 > > > > > > +++++++++++++++++++++ > > > > > > drivers/thermal/qcom/qmi-cooling.h | 428 > > > > > > +++++++++++++++++ > > > > > > 10 files changed, 1161 insertions(+), 8 deletions(-) > > > > > > --- > > > > > > base-commit: 9067f80db58bbce81d5f0703aa2fd261e88bc812 > > > > > > > > > > > > // Caleb (they/them) > > > > > > > > > > > > > > > > > > > -- > > > > // Caleb (they/them) > > > > > > -- > > > மணிவண்ணன் சதாசிவம் > > > > > > > > -- > > With best wishes > > Dmitry > > -- > மணிவண்ணன் சதாசிவம் -- With best wishes Dmitry