All local setup of the generic_pm_domain structure should have been
completed before calling pm_genpd_init().

Signed-off-by: Geert Uytterhoeven <[email protected]>
---
 drivers/clk/renesas/clk-mstp.c | 3 +--
 1 file changed, 1 insertion(+), 2 deletions(-)

diff --git a/drivers/clk/renesas/clk-mstp.c b/drivers/clk/renesas/clk-mstp.c
index 8b597b9a380442e8..969fbb61ab07b9b8 100644
--- a/drivers/clk/renesas/clk-mstp.c
+++ b/drivers/clk/renesas/clk-mstp.c
@@ -316,11 +316,10 @@ void __init cpg_mstp_add_clk_domain(struct device_node 
*np)
                return;
 
        pd->name = np->name;
-
        pd->flags = GENPD_FLAG_PM_CLK;
-       pm_genpd_init(pd, &simple_qos_governor, false);
        pd->attach_dev = cpg_mstp_attach_dev;
        pd->detach_dev = cpg_mstp_detach_dev;
+       pm_genpd_init(pd, &simple_qos_governor, false);
 
        of_genpd_add_provider_simple(np, pd);
 }
-- 
1.9.1