Hi Jacopo,

On Fri, Mar 24, 2017 at 4:28 PM, Jacopo Mondi <jacopo+rene...@jmondi.org> wrote:
> output reported from iio_info tool:
> iio:device0: max9611_vdd
>                 6 channels found:

>                         temp:  (input)
>                         2 channel-specific attributes found:
>                                 attr 0: scale value: 0.480076812
>                                 attr 1: raw value: 59

According to Documentation/ABI/testing/sysfs-bus-iio, temperature units after
application of scale and offset are milli degrees Celsius, so your scale value
should be 480.076812.

BTW, mine runs 3 degrees cooler, but it's located in the coldest room in my
house ;-)

Gr{oetje,eeting}s,

                        Geert

--
Geert Uytterhoeven -- There's lots of Linux beyond ia32 -- ge...@linux-m68k.org

In personal conversations with technical people, I call myself a hacker. But
when I'm talking to journalists I just say "programmer" or something like that.
                                -- Linus Torvalds

Reply via email to