From: Niklas Söderlund <[email protected]>

Change the upper limit to clamp the high temperature value to 120C when
setting trip points.

Signed-off-by: Niklas Söderlund <[email protected]>
---
 drivers/thermal/rcar_gen3_thermal.c | 4 ++--
 1 file changed, 2 insertions(+), 2 deletions(-)

diff --git a/drivers/thermal/rcar_gen3_thermal.c 
b/drivers/thermal/rcar_gen3_thermal.c
index 79c2cdb4105fc0b8..3905ec8b2689827c 100644
--- a/drivers/thermal/rcar_gen3_thermal.c
+++ b/drivers/thermal/rcar_gen3_thermal.c
@@ -207,8 +207,8 @@ static int rcar_gen3_thermal_set_trips(void *devdata, int 
low, int high)
 {
        struct rcar_gen3_thermal_tsc *tsc = devdata;
 
-       low = clamp_val(low, -40000, 125000);
-       high = clamp_val(high, -40000, 125000);
+       low = clamp_val(low, -40000, 120000);
+       high = clamp_val(high, -40000, 120000);
 
        rcar_gen3_thermal_write(tsc, REG_GEN3_IRQTEMP1,
                                rcar_gen3_thermal_mcelsius_to_temp(tsc, low));
-- 
2.17.0