Hi Geert,

On Friday, 8 June 2018 14:53:28 EEST Geert Uytterhoeven wrote:
> On Fri, Jun 8, 2018 at 1:18 PM Laurent Pinchart wrote:
> > The R8A77995 VSP and FCP nodes have overlapping register ranges, as the
> > SoC integrates the FCP devices in the memory range usually used by the
> > VSP LUT and CLUT, which are not present. Fix this by shortening the VSP
> > registers range to 0x5000.
> 
> According to datasheet rev. 1.00, the CLUT is present on R-Car D3, the
> LUT is not.

That was a typo, the commit message should have mentioned CLU, not CLUT. I've 
sent a v2 that fixes this and covers the H3 and M3* SoCs.

> > Fixes: 295952a183d3 ("arm64: dts: renesas: r8a77995: add VSP instances")
> > Reported-by: Simon Horman <[email protected]>
> > Reported-by: Geert Uytterhoeven <[email protected]>
> > Signed-off-by: Laurent Pinchart
> > <[email protected]>
> 
> Apart from my comment above:
> Reviewed-by: Geert Uytterhoeven <[email protected]>

-- 
Regards,

Laurent Pinchart



Reply via email to