When trying to use I2C7 on R-Car E3:
renesas-cpg-mssr e6150000.clock-controller: Cannot get module clock 1003: -2
i2c-rcar e6690000.i2c: failed to add to PM domain always-on: -2
i2c-rcar: probe of e6690000.i2c failed with error -2
Unlike other R-Car Gen3 SoCs, R-Car E3 has more than 7 I2C bus
interfaces. Add the forgotten module clock for the 8th instance to fix
this.
Signed-off-by: Geert Uytterhoeven <[email protected]>
---
To be queued in clk-renesas-for-v4.20.
drivers/clk/renesas/r8a77990-cpg-mssr.c | 1 +
1 file changed, 1 insertion(+)
diff --git a/drivers/clk/renesas/r8a77990-cpg-mssr.c
b/drivers/clk/renesas/r8a77990-cpg-mssr.c
index 9437219efdd98e34..7e000d0705891a3f 100644
--- a/drivers/clk/renesas/r8a77990-cpg-mssr.c
+++ b/drivers/clk/renesas/r8a77990-cpg-mssr.c
@@ -210,6 +210,7 @@ static const struct mssr_mod_clk r8a77990_mod_clks[]
__initconst = {
DEF_MOD("i2c1", 930, R8A77990_CLK_S3D2),
DEF_MOD("i2c0", 931, R8A77990_CLK_S3D2),
+ DEF_MOD("i2c7", 1003, R8A77990_CLK_S3D2),
DEF_MOD("ssi-all", 1005, R8A77990_CLK_S3D4),
DEF_MOD("ssi9", 1006, MOD_CLK_ID(1005)),
DEF_MOD("ssi8", 1007, MOD_CLK_ID(1005)),
--
2.17.1