On r8a7791/koelsch:

    m25p80 spi0.0: error -22 reading 9f
    m25p80: probe of spi0.0 failed with error -22

Apparently the logic in spi_mem_check_op() is wrong, rejecting the
spi-mem operation if any buswidth is valid, instead of invalid.

Fixes: 380583227c0c7f52 ("spi: spi-mem: Add extra sanity checks on the op 
param")
Signed-off-by: Geert Uytterhoeven <geert+rene...@glider.be>
---
 drivers/spi/spi-mem.c | 8 ++++----
 1 file changed, 4 insertions(+), 4 deletions(-)

diff --git a/drivers/spi/spi-mem.c b/drivers/spi/spi-mem.c
index cc3d425aae56c634..62a7b80801d22098 100644
--- a/drivers/spi/spi-mem.c
+++ b/drivers/spi/spi-mem.c
@@ -169,10 +169,10 @@ static int spi_mem_check_op(const struct spi_mem_op *op)
            (op->data.nbytes && !op->data.buswidth))
                return -EINVAL;
 
-       if (spi_mem_buswidth_is_valid(op->cmd.buswidth) ||
-           spi_mem_buswidth_is_valid(op->addr.buswidth) ||
-           spi_mem_buswidth_is_valid(op->dummy.buswidth) ||
-           spi_mem_buswidth_is_valid(op->data.buswidth))
+       if (!spi_mem_buswidth_is_valid(op->cmd.buswidth) ||
+           !spi_mem_buswidth_is_valid(op->addr.buswidth) ||
+           !spi_mem_buswidth_is_valid(op->dummy.buswidth) ||
+           !spi_mem_buswidth_is_valid(op->data.buswidth))
                return -EINVAL;
 
        return 0;
-- 
2.17.1