On Fri, Aug 16, 2019 at 02:22:29PM +0200, Geert Uytterhoeven wrote:
> Hook up HSCIF serial devices that are part of the CPG/MSTP Clock Domain
> to the SYSC "always-on" PM Domain, for a more consistent
> device-power-area description in DT.
> 
> Cfr. commit 751e29bbb64ad091 ("ARM: dts: r8a7779: Use SYSC "always-on" PM 
> Domain").
> 
> Fixes: 055d15a88f66b096 ("ARM: dts: r8a7779: Add HSCIF0/1 device nodes")
> Signed-off-by: Geert Uytterhoeven <[email protected]>

Reviewed-by: Simon Horman <[email protected]>

> ---
> To be queued in renesas-devel for v5.4.
> 
>  arch/arm/boot/dts/r8a7779.dtsi | 4 ++--
>  1 file changed, 2 insertions(+), 2 deletions(-)
> 
> diff --git a/arch/arm/boot/dts/r8a7779.dtsi b/arch/arm/boot/dts/r8a7779.dtsi
> index 3ff2592075275555..ebf5b7cfe21599c6 100644
> --- a/arch/arm/boot/dts/r8a7779.dtsi
> +++ b/arch/arm/boot/dts/r8a7779.dtsi
> @@ -296,7 +296,7 @@
>                        <&cpg_clocks R8A7779_CLK_S>,
>                        <&scif_clk>;
>               clock-names = "fck", "brg_int", "scif_clk";
> -             power-domains = <&cpg_clocks>;
> +             power-domains = <&sysc R8A7779_PD_ALWAYS_ON>;
>               status = "disabled";
>       };
>  
> @@ -309,7 +309,7 @@
>                        <&cpg_clocks R8A7779_CLK_S>,
>                        <&scif_clk>;
>               clock-names = "fck", "brg_int", "scif_clk";
> -             power-domains = <&cpg_clocks>;
> +             power-domains = <&sysc R8A7779_PD_ALWAYS_ON>;
>               status = "disabled";
>       };
>  
> -- 
> 2.17.1
> 

Reply via email to