Replace pdata->test_mux check in get_con_reg() by explicitly
checking for SoC type.

Also since the used pdata->test_mux value is always identical
use it directly and remove pdata->test_mux completely.

There should be no functional changes caused by this patch.

Cc: Naveen Krishna Chatradhi <ch.nav...@samsung.com>
Cc: Amit Daniel Kachhap <amit.dan...@samsung.com>
Cc: Lukasz Majewski <l.majew...@samsung.com>
Cc: Eduardo Valentin <edubez...@gmail.com>
Cc: Zhang Rui <rui.zh...@intel.com>
Signed-off-by: Bartlomiej Zolnierkiewicz <b.zolnier...@samsung.com>
Acked-by: Kyungmin Park <kyungmin.p...@samsung.com>
---
 drivers/thermal/samsung/exynos_tmu.c      | 5 +++--
 drivers/thermal/samsung/exynos_tmu.h      | 2 --
 drivers/thermal/samsung/exynos_tmu_data.c | 2 --
 3 files changed, 3 insertions(+), 6 deletions(-)

diff --git a/drivers/thermal/samsung/exynos_tmu.c 
b/drivers/thermal/samsung/exynos_tmu.c
index 367f4eb..80961e3 100644
--- a/drivers/thermal/samsung/exynos_tmu.c
+++ b/drivers/thermal/samsung/exynos_tmu.c
@@ -193,8 +193,9 @@ static u32 get_con_reg(struct exynos_tmu_data *data, u32 
con)
 {
        struct exynos_tmu_platform_data *pdata = data->pdata;
 
-       if (pdata->test_mux)
-               con |= (pdata->test_mux << EXYNOS4412_MUX_ADDR_SHIFT);
+       if (data->soc == SOC_ARCH_EXYNOS4412 ||
+           data->soc == SOC_ARCH_EXYNOS3250)
+               con |= (EXYNOS4412_MUX_ADDR_VALUE << EXYNOS4412_MUX_ADDR_SHIFT);
 
        con &= ~(EXYNOS_TMU_REF_VOLTAGE_MASK << EXYNOS_TMU_REF_VOLTAGE_SHIFT);
        con |= pdata->reference_voltage << EXYNOS_TMU_REF_VOLTAGE_SHIFT;
diff --git a/drivers/thermal/samsung/exynos_tmu.h 
b/drivers/thermal/samsung/exynos_tmu.h
index 2eb4cb9..8de0f82 100644
--- a/drivers/thermal/samsung/exynos_tmu.h
+++ b/drivers/thermal/samsung/exynos_tmu.h
@@ -89,7 +89,6 @@ enum soc_type {
  * @first_point_trim: temp value of the first point trimming
  * @second_point_trim: temp value of the second point trimming
  * @default_temp_offset: default temperature offset in case of no trimming
- * @test_mux; information if SoC supports test MUX
  * @cal_type: calibration type for temperature
  * @freq_clip_table: Table representing frequency reduction percentage.
  * @freq_tab_count: Count of the above table as frequency reduction may
@@ -115,7 +114,6 @@ struct exynos_tmu_platform_data {
        u8 first_point_trim;
        u8 second_point_trim;
        u8 default_temp_offset;
-       u8 test_mux;
 
        enum calibration_type cal_type;
        enum soc_type type;
diff --git a/drivers/thermal/samsung/exynos_tmu_data.c 
b/drivers/thermal/samsung/exynos_tmu_data.c
index d90b050..708c3e1 100644
--- a/drivers/thermal/samsung/exynos_tmu_data.c
+++ b/drivers/thermal/samsung/exynos_tmu_data.c
@@ -109,7 +109,6 @@ struct exynos_tmu_init_data const 
exynos3250_default_tmu_data = {
                {
                        EXYNOS3250_TMU_DATA,
                        .type = SOC_ARCH_EXYNOS3250,
-                       .test_mux = EXYNOS4412_MUX_ADDR_VALUE,
                },
        },
        .tmu_count = 1,
@@ -160,7 +159,6 @@ struct exynos_tmu_init_data const 
exynos4412_default_tmu_data = {
                {
                        EXYNOS4412_TMU_DATA,
                        .type = SOC_ARCH_EXYNOS4412,
-                       .test_mux = EXYNOS4412_MUX_ADDR_VALUE,
                },
        },
        .tmu_count = 1,
-- 
1.8.2.3

--
To unsubscribe from this list: send the line "unsubscribe linux-samsung-soc" in
the body of a message to majord...@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html

Reply via email to