Hello,

On 2015-02-09 11:58, Krzysztof Kozlowski wrote:
2015-02-09 10:06 GMT+01:00 Krzysztof Kozlowski <[email protected]>:
2015-02-09 8:25 GMT+01:00 Marek Szyprowski <[email protected]>:
PS_HOLD based power off procedure is common for all Exynos SoCs, so use
it for every Exynos SoC.

Signed-off-by: Marek Szyprowski <[email protected]>
---
  arch/arm/mach-exynos/pmu.c | 6 +++---
  1 file changed, 3 insertions(+), 3 deletions(-)
I tried this on Trats2 board (Exynos 4412) and message "Power down
failed, please power off system manually." appears. Is it expected? Or
am I missing some patches (I applied this on top of next-20150129)?
It was my fault (I left attached JIG cable which prevents power off).
Now it works fine.

Tested on Trats2 (Exynos4412):
Tested-by: Krzysztof Kozlowski <[email protected]>

Patch also looks good, so:
Reviewed-by: Krzysztof Kozlowski <[email protected]>

Gentle ping for merging this in v4.1-next...

Best regards
--
Marek Szyprowski, PhD
Samsung R&D Institute Poland

--
To unsubscribe from this list: send the line "unsubscribe linux-samsung-soc" in
the body of a message to [email protected]
More majordomo info at  http://vger.kernel.org/majordomo-info.html

Reply via email to