On 03/18/2016 05:49 AM, Damien Le Moal wrote:
> 
> libata: Set longer timeout for SETFEATURES_SPINUP
>     
> For SATA drives with power-up in standby (PUIS) feature set,
> SETFEATURES_SPINUP execution may be required to get
> complete IDENTIFY data. However, the timeout used for its
> execution is the same as for all other SETFEATURES commands,
> that is, 5 seconds. This is too short for some disks to complete
> timeout and allow IDENTIFY to return complete data (e.g.
> disks with large indirection tables stored on media), resulting
> in ata_dev_read_id to fail. For this feature, allow a larger
> timeout of 30 seconds.
> 
Reviewed-by: Hannes Reinecke <[email protected]>

(BTW, you might want to add your Signed-off-by:, too :-)

Cheers,

Hannes
-- 
Dr. Hannes Reinecke                Teamlead Storage & Networking
[email protected]                                   +49 911 74053 688
SUSE LINUX GmbH, Maxfeldstr. 5, 90409 Nürnberg
GF: F. Imendörffer, J. Smithard, J. Guild, D. Upmanyu, G. Norton
HRB 21284 (AG Nürnberg)
--
To unsubscribe from this list: send the line "unsubscribe linux-scsi" in
the body of a message to [email protected]
More majordomo info at  http://vger.kernel.org/majordomo-info.html

Reply via email to