On Sat, Dec 01, 2018 at 12:34:19AM +0100, David Disseldorp wrote:
> spc5r17.pdf specifies:
>   4.3.1 ASCII data field requirements
>   ASCII data fields shall contain only ASCII printable characters (i.e.,
>   code values 20h to 7Eh) and may be terminated with one or more ASCII
>   null (00h) characters.
>   ASCII data fields described as being left-aligned shall have any
>   unused bytes at the end of the field (i.e., highest offset) and the
>   unused bytes shall be filled with ASCII space characters (20h).
> 
> LIO currently space-pads the T10 VENDOR IDENTIFICATION and PRODUCT
> IDENTIFICATION fields in the standard INQUIRY data. However, the
> PRODUCT REVISION LEVEL field in the standard INQUIRY data as well as the
> T10 VENDOR IDENTIFICATION field in the INQUIRY Device Identification VPD
> Page are zero-terminated/zero-padded.
> 
> Fix this inconsistency by using space-padding for all of the above
> fields.
> 
> Signed-off-by: David Disseldorp <[email protected]>
> Reviewed-by: Christoph Hellwig <[email protected]>
> Reviewed-by: Bryant G. Ly <[email protected]>
> Reviewed-by: Lee Duncan <[email protected]>
> ---
>  drivers/target/target_core_spc.c | 17 ++++++++++++-----
>  1 file changed, 12 insertions(+), 5 deletions(-)
> 

Reviewed-by: Roman Bolshakov <[email protected]>