https://bugzilla.kernel.org/show_bug.cgi?id=199703

Loic S. ([email protected]) changed:

           What    |Removed                     |Added
----------------------------------------------------------------------------
                 CC|                            |[email protected]

--- Comment #31 from Loic S. ([email protected]) ---
Hi

I had the same issue. HP Smart Array P400 controller in a HP DL385 migrating
from Ubuntu 16.04 to 18.04, so a kernel going from 4.10.xx to 4.15.yy and
kernel couldn't find the disk controller.

I tried all the hpsa_xx, cciss_xx and rootdelay combinations in the boot
parameters with no results. I ended up upgrading the P400 firmware (4.08 to
7.24) and it worked straight without any parameter change.

Server and disk access is still ok after a few days of testing.

Thanks for the tip.
Loic

-- 
You are receiving this mail because:
You are the assignee for the bug.

Reply via email to