Richard Talbot <[EMAIL PROTECTED]> wrote: > [root@talbot /root]# mt -f /dev/st0 retension Do you do that as the same time as you run Arkeia ? Arkeia is going to try the /dev/sgX interface (for extended tape status), and it may have very short timeouts. So if your retension takes 2 minutes, /dev/sgX default timeout is guaranteed to cause a bus reset. - To unsubscribe from this list: send the line "unsubscribe linux-scsi" in the body of a message to [EMAIL PROTECTED]