> Hi,
> 
> On Thu, Aug 10, 2000 at 07:33:50PM -0500, David Teigland wrote:
> > I'm interested in combining two or more active hosts with multiple devices on a
> > single parallel SCSI bus.  I've successfully done this, but don't know the
> > extent of problems which could arise when hosts or disks are added or removed
> > (crashed) on the in-use bus.
> 
> Yes, multi-initiator environments are well defined in SCSI.

Take great care that the bus is terminated correctly at all times.  In 
particular some devices (Adaptec 2944UW in particular) uses termination 
controlled by BIOS.  Since BIOS determines what and when to terminate.  No 
power, no termination.  Using shunts you can force termination.

As with any termination problem you will see bizarre and unpredictable 
failures.

Eddie Williams



-
To unsubscribe from this list: send the line "unsubscribe linux-scsi" in
the body of a message to [EMAIL PROTECTED]

Reply via email to