John Cheetham
[EMAIL PROTECTED]
ffffd000 (fec00000)
relocating initrd image:
initrd_start:0xc0f95000 initrd_end:0xc0fff78c
mem_start:0xc028a000 mem_end:0xfc000000
initrd_size:0x0006a78c dest:0xfbf95000
Detected 930976970 Hz processor.
Console: colour VGA+ 80x25
Calibrating delay loop... 927.33 BogoMIPS
Memory: 1035292k/1048128k available (1132k kernel code, 420k reserved, 10780k data,
76k init, 65088k bigmem)
Dentry hash table entries: 262144 (order 9, 2048k)
Buffer cache hash table entries: 524288 (order 9, 2048k)
Page cache hash table entries: 262144 (order 8, 1024k)
VFS: Diskquotas version dquot_6.4.0 initialized
Checking 386/387 coupling... OK, FPU using exception 16 error reporting.
Checking 'hlt' instruction... OK.
POSIX conformance testing by UNIFIX
mtrr: v1.35a (19990819) Richard Gooch ([EMAIL PROTECTED])
per-CPU timeslice cutoff: 50.05 usecs.
CPU0: Intel Pentium III (Coppermine) stepping 03
calibrating APIC timer ...
..... CPU clock speed is 930.9748 MHz.
..... system bus clock speed is 132.9963 MHz.
Booting processor 1 eip 2000
Calibrating delay loop... 930.61 BogoMIPS
OK.
CPU1: Intel Pentium III (Coppermine) stepping 03
Total of 2 processors activated (1857.95 BogoMIPS).
enabling symmetric IO mode... ...done.
ENABLING IO-APIC IRQs
...changing IO-APIC physical APIC ID to 2
init IO_APIC IRQs
IO-APIC (apicid-pin) 2-0, 2-13, 2-20, 2-21, 2-22, 2-23 not connected.
number of MP IRQ sources: 44.
number of IO-APIC #2 registers: 24.
testing the IO APIC.......................
IO APIC #2......
.... register #00: 02000000
....... : physical APIC id: 02
.... register #01: 00170020
....... : max redirection entries: 0017
....... : IO APIC version: 0020
WARNING: unexpected IO-APIC, please mail
to [EMAIL PROTECTED]
.... register #02: 00000000
....... : arbitration: 00
.... IRQ redirection table:
NR Log Phy Mask Trig IRR Pol Stat Dest Deli Vect:
00 000 00 1 0 0 0 0 0 0 00
01 000 00 0 0 0 0 0 1 1 59
02 0FF 0F 0 0 0 0 0 1 1 51
03 000 00 0 0 0 0 0 1 1 61
04 000 00 0 0 0 0 0 1 1 69
05 000 00 0 0 0 0 0 1 1 71
06 000 00 0 0 0 0 0 1 1 79
07 000 00 0 0 0 0 0 1 1 81
08 000 00 0 0 0 0 0 1 1 89
09 000 00 0 0 0 0 0 1 1 91
0a 000 00 0 0 0 0 0 1 1 99
0b 000 00 0 0 0 0 0 1 1 A1
0c 000 00 0 0 0 0 0 1 1 A9
0d 000 00 1 0 0 0 0 0 0 00
0e 000 00 0 0 0 0 0 1 1 B1
0f 000 00 0 0 0 0 0 1 1 B9
10 0FF 0F 1 1 0 1 0 1 1 C1
11 0FF 0F 1 1 0 1 0 1 1 C9
12 0FF 0F 1 1 0 1 0 1 1 D1
13 0FF 0F 1 1 0 1 0 1 1 D9
14 000 00 1 0 0 0 0 0 0 00
15 000 00 1 0 0 0 0 0 0 00
16 000 00 1 0 0 0 0 0 0 00
17 000 00 1 0 0 0 0 0 0 00
IRQ to pin mappings:
IRQ0 -> 2
IRQ1 -> 1
IRQ3 -> 3
IRQ4 -> 4
IRQ5 -> 5
IRQ6 -> 6
IRQ7 -> 7
IRQ8 -> 8
IRQ9 -> 9
IRQ10 -> 10
IRQ11 -> 11
IRQ12 -> 12
IRQ14 -> 14
IRQ15 -> 15
IRQ16 -> 16
IRQ17 -> 17
IRQ18 -> 18
IRQ19 -> 19
.................................... done.
checking TSC synchronization across CPUs: passed.
PCI: PCI BIOS revision 2.10 entry at 0xfc04e
PCI: Using configuration type 1
PCI: Probing PCI hardware
PCI->APIC IRQ transform: (B0,I31,P3) -> 19
PCI->APIC IRQ transform: (B0,I31,P1) -> 17
PCI->APIC IRQ transform: (B2,I4,P0) -> 16
PCI->APIC IRQ transform: (B2,I8,P0) -> 16
PCI->APIC IRQ transform: (B2,I9,P0) -> 17
PCI->APIC IRQ transform: (B3,I10,P0) -> 18
PCI->APIC IRQ transform: (B3,I10,P1) -> 19
Linux NET4.0 for Linux 2.2
Based upon Swansea University Computer Society NET3.039
NET4: Unix domain sockets 1.0 for Linux NET4.0.
NET4: Linux TCP/IP 1.0 for NET4.0
IP Protocols: ICMP, UDP, TCP, IGMP
TCP: Hash tables configured (ehash 524288 bhash 65536)
Initializing RT netlink socket
Starting kswapd v 1.5
Detected PS/2 Mouse Port.
Serial driver version 4.27 with MANY_PORTS MULTIPORT SHARE_IRQ enabled
ttyS00 at 0x03f8 (irq = 4) is a 16550A
ttyS01 at 0x02f8 (irq = 3) is a 16550A
pty: 256 Unix98 ptys configured
Real Time Clock Driver v1.09
RAM disk driver initialized: 16 RAM disks of 4096K size
PCI_IDE: unknown IDE controller on PCI bus 00 device f9, VID=8086, DID=2411
PCI_IDE: not 100% native mode: will probe irqs later
ide0: BM-DMA at 0xffa0-0xffa7, BIOS settings: hda:pio, hdb:pio
ide1: BM-DMA at 0xffa8-0xffaf, BIOS settings: hdc:DMA, hdd:pio
hdc: Lite-On LTN483S 48x Max, ATAPI CDROM drive
ide1 at 0x170-0x177,0x376 on irq 15
hdc: ATAPI 48X CD-ROM drive, 120kB Cache
Uniform CDROM driver Revision: 2.56
Floppy drive(s): fd0 is 1.44M
FDC 0 is a National Semiconductor PC87306
md driver 0.90.0 MAX_MD_DEVS=256, MAX_REAL=12
raid5: measuring checksumming speed
raid5: MMX detected, trying high-speed MMX checksum routines
pII_mmx : 2087.499 MB/sec
p5_mmx : 2180.082 MB/sec
8regs : 1600.581 MB/sec
32regs : 940.689 MB/sec
using fastest function: p5_mmx (2180.082 MB/sec)
scsi : 0 hosts.
scsi : detected total.
md.c: sizeof(mdp_super_t) = 4096
Partition check:
RAMDISK: Compressed image found at block 0
autodetecting RAID arrays
autorun ...
... autorun DONE.
VFS: Mounted root (ext2 filesystem).
(scsi0) <Adaptec AIC-7899 Ultra 160/m SCSI host adapter> found at PCI 3/10/0
(scsi0) Wide Channel A, SCSI ID=7, 32/255 SCBs
(scsi0) Downloading sequencer code... 396 instructions downloaded
enable_irq() unbalanced from fc81bb26
(scsi1) <Adaptec AIC-7899 Ultra 160/m SCSI host adapter> found at PCI 3/10/1
(scsi1) Wide Channel B, SCSI ID=7, 32/255 SCBs
(scsi1) Downloading sequencer code... 396 instructions downloaded
enable_irq() unbalanced from fc81bb26
scsi0 : Adaptec AHA274x/284x/294x (EISA/VLB/PCI-Fast SCSI) 5.1.28/3.2.4
<Adaptec AIC-7899 Ultra 160/m SCSI host adapter>
scsi1 : Adaptec AHA274x/284x/294x (EISA/VLB/PCI-Fast SCSI) 5.1.28/3.2.4
<Adaptec AIC-7899 Ultra 160/m SCSI host adapter>
scsi : 2 hosts.
(scsi0:0:0:0) Synchronous at 160.0 Mbyte/sec, offset 127.
Vendor: FUJITSU Model: MAG3182MP Rev: 5506
Type: Direct-Access ANSI SCSI revision: 03
Detected scsi disk sda at scsi0, channel 0, id 0, lun 0
SCSI device sda: hdwr sector= 512 bytes. Sectors= 35566499 [17366 MB] [17.4 GB]
sda: sda1 sda2 sda3
autodetecting RAID arrays
autorun ...
... autorun DONE.
VFS: Mounted root (ext2 filesystem) readonly.
change_root: old root has d_count=1
Trying to unmount old root ... okay
Freeing unused kernel memory: 76k freed
Adding Swap: 514072k swap-space (priority -1)
3c59x.c:v0.99H 11/17/98 Donald Becker
http://cesdis.gsfc.nasa.gov/linux/drivers/vortex.html
eth0: 3Com 3c905C Tornado at 0xdc80, ***INVALID CHECKSUM 0060*** 00:b0:d0:3d:79:a6,
IRQ 16
8K byte-wide RAM 5:3 Rx:Tx split, autoselect/Autonegotiate interface.
MII transceiver found at address 24, status 782d.
Enabling bus-master transmits and whole-frame receives.
Installing knfsd (copyright (C) 1996 [EMAIL PROTECTED]).
nfsd_fh_init : initialized fhcache, entries=1024
exp_do_unexport: 08:03 last use, flushing cache
nfsd: terminating on signal 9
nfsd: terminating on signal 9
nfsd: terminating on signal 9
nfsd: terminating on signal 9
nfsd: terminating on signal 9
nfsd: terminating on signal 9
nfsd: terminating on signal 9
nfsd: terminating on signal 9
nfsd: last server exiting
nfsd_fh_shutdown : freeing 1024 fhcache entries.
nfsd_fh_init : initialized fhcache, entries=1024