On Thu, Aug 14, 2014 at 12:34 AM, [email protected] <[email protected]> wrote:
> Is there any way to generate a clock on a pin with the A20 other than
> the two PWM units? I just need a simple, always on clock.
>
> I need another clock because apparently you can't put I2S into slave
> mode as long as MCLKEN (ie MCLK on a pin) is enabled.

The A20 has 2 clock outputs, CLK_OUT_A and CLK_OUT_B.
The outputs are muxed on PI13 and PI14.

The clocks have configurable dividers, and can be sourced from
osc24M or osc32k. See page 92 of the A20's user manual.