On Sat, Sep 06, 2014 at 06:47:28PM +0800, Chen-Yu Tsai wrote:
> The sun6i DMA controller requires the AHB1 bus clock to be
> clocked from PLL6. This was originally done by the dmaengine
> driver during probe time. The AHB1 clock driver has since been
> unified, so the original code does not work.
> 
> Remove the clk muxing code, and replace it with DT clk default
> properties.

Applied, thanks

-- 
~Vinod

-- 
You received this message because you are subscribed to the Google Groups 
"linux-sunxi" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to linux-sunxi+unsubscr...@googlegroups.com.
For more options, visit https://groups.google.com/d/optout.

Reply via email to