On Wed, Jan 27, 2021 at 05:24:56PM +0000, Andre Przywara wrote:
> The Allwinner H616 SoC has two EMAC controllers, with the second one
> being tied to the internal PHY, but also using a separate EMAC clock
> register.
> 
> To tell the driver about which clock register to use, we add a parameter
> to our syscon phandle. The driver will use this value as an index into
> the regmap, so that we can address more than the first register, if
> needed.
> 
> Signed-off-by: Andre Przywara <[email protected]>

Acked-by: Maxime Ripard <[email protected]>

Maxime

-- 
You received this message because you are subscribed to the Google Groups 
"linux-sunxi" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
To view this discussion on the web, visit 
https://groups.google.com/d/msgid/linux-sunxi/20210128102124.5r7ztgehw2iqbbl6%40gilmour.