On 08/03/2012 12:11 PM, Stephen Warren wrote:
> Whistler uses a Maxim 8907 regulator. Instantiate this.
> 
> The voltage settings were derived from the schematic. The only exception
> is the BBAT voltage; the schematic says 1.2v, but the HW can't go that
> low, so use the HW default of 2.4v instead.
> 
> Almost all regulators list all driven supply signal names in their
> regulator-names property. The exception is nvvdd_sv3, which is in turn
> named 12 more different names on the schematic, so these were omitted
> for brevity.