On Thu, Dec 20, 2012 at 03:30:03AM +0100, Joseph Lo wrote:
> The power up sequence is different on the cold boot CPU and the CPU
> that resumed from the hotplug. For the cold boot CPU, it was been power
> gated as default. To power up the cold boot CPU, the power should be
> un-gated by un toggling the power gate register manually.
> 
> For the CPU that resumed from the hotplug, after un-halted the CPU. The
> flow controller will un-gate the power of the CPU. No need to manually
> control, just wait the power be resumed and continue the power up
> sequence after the CPU power is ready.
> 
> Based on the work by:
> Varun Wadekar <[email protected]>
> 
> Signed-off-by: Joseph Lo <[email protected]>

Acked-by: Peter De Schrijver <[email protected]>
--
To unsubscribe from this list: send the line "unsubscribe linux-tegra" in
the body of a message to [email protected]
More majordomo info at  http://vger.kernel.org/majordomo-info.html

Reply via email to