Hi, On 2.5.73 (and probably previously, I think I've seen this before), when disconnecting a USB device from a UHCI host, I sometimes get the following "errors" in my log.
drivers/usb/host/uhci-hcd.c: uhci_result_common() failed with status 440000 [dec132a0] link (1ec13152) element (1ec00060) 0: [dec00060] link (00000001) e0 SPD IOC Stalled CRC/Timeo Length=7ff MaxLen=1f DT0 EndPt=2 Dev=3, PID=69(IN) (buf=1f9c8ec0) They repeat continuously, and don't stop until I reboot the machine (spitting these out to the serial log usually takes up 100% of the cpu so I can't unload the module to see if that stops it.) Any ideas of how to fix this, or even what is causing this continuous message (I can see it happening once, but not more than once.) This happens for my usb trackball, and for a variety of different usb-serial devices. It doesn't seem to happen at all on ohci. thanks, greg k-h ------------------------------------------------------- This SF.Net email sponsored by: Free pre-built ASP.NET sites including Data Reports, E-commerce, Portals, and Forums are available now. Download today and enter to win an XBOX or Visual Studio .NET. http://aspnet.click-url.com/go/psa00100006ave/direct;at.asp_061203_01/01 _______________________________________________ [EMAIL PROTECTED] To unsubscribe, use the last form field at: https://lists.sourceforge.net/lists/listinfo/linux-usb-devel