hi , i do not use windows, its a linux mailinglist
but in linux my config for nokia 3220 is this:
[gammu]

port = /dev/ttyUSB0
model = 3220
connection = fbuspl2303
#synchronizetime = yes
#logfile = gammulog
#logformat = textall
use_locking = yes
#gammuloc = locfile
startinfo = yes
#gammucoding = utf8

my cable is a pl2303 chipset , dku5 now called CA-42 i think.
i think that you have the port setting mistake maybe must be com3 or com4 or 
someelse.
otherwise, you must search specific support for gammu in the gammu 
website/mailinglists.
i hope that help you.

Saludos!

El Lunes 20 Febrero 2006 19:42, escribió:
> Good day Fernando!
>
>  I came across your website as I was searching on how to make my Nokia 3200
> phone be connected to my PC using Gammu. I'm a newbie on Gammu so I don't
> have much knowledge on how to configure it. I have a cable (DKU-5) that
> connects to the PC via a USB plug. I used it to connect the Nokia 3200 to
> my PC but when I set the gammurc file config to:
>
>  [gammu]
>
>  port = dku5
>  model = 3200
>  connection = dku5fbus
>  #synchronizetime = yes
>  #logfile = gammulog
>  #logformat = textall
>  #use_locking = yes
>  #gammuloc = locfile
>  #startinfo = yes
>  #gammucoding = utf8
>
>  [gammu1]
>
>  port = dku5
>  #model = 6110
>  connection = dku5fbus
>  #synchronizetime = yes
>  #logfile = gammulog
>  #logformat = textall
>  #use_locking = yes
>  #gammuloc = locfile
>  #startinfo = yes
>  #gammucoding = utf8
>
>
>
>  (I'm not even sure as to why there's a second "gammu1" config, I only
> wanted to use one of them)
>
>   the error gammu displays using the gammu textall --identify on my MS-DOS
> prompt (I'm using Windows XP with SP2) is
>
>  [Gammu            - 1.03.00 built 21:41:50 Oct 17 2005 in MS VC .NET 2003]
>  [Connection       - "dku5fbus"]
>  [Model type       - "3200"]
>  [Device           - "dku5"]
>  [Run on           - Win XP Pro SP2]
>  [Module           -
> "1100|1100a|1100b|3100|3100b|3105|3108|3200|3200a|3220|3300|
> 3510|3510i|3530|3589i|3590|3595|5100|5140|6020|6100|6200|6220|6230|6230i|63
>10|63
> 10i|6385|6510|6610|6610i|6800|6810|6820|7200|7210|7250|7250i|7600|8310|8390
>|8910
>
>  |8910i"]
>
>  Reading DKU5 device
>  Error opening key
>  [Gammu            - 1.03.00 built 21:41:50 Oct 17 2005 in MS VC .NET 2003]
>  [Connection       - "dku5fbus"]
>  [Model type       - ""]
>  [Device           - "dku5"]
>  [Run on           - Win XP Pro SP2]
>  Reading DKU5 device
>  Error opening key
>  [ERROR 8: Error opening device. Some hardware not connected/wrong
> configured.] Error opening device. Some hardware not connected/wrong
> configured.
>
>
>
>
>  If you have some tips to solve this problem I would be really thankful. :)
> I'm really desperate to get this connection up and running because it
> concerns my project in Computer Science. I hope to hear from you soon and
> God bless. :)
>
>
>  --ronx

-- 
http://www.docksud.com.ar
telnet://bbs.docksud.com.ar

* Canal irc de #solar en freenode - irc://irc.freenode.net#solar *

Attachment: pgpnkESFEKECD.pgp
Description: PGP signature

Reply via email to