Yes, Ali Laukkanen submitted a patch to make hc_reset()
return -1 on errors and its caller to abort if
hc_reset() < 0. I forwarded it to Linus yesterday.
~Randy
___________________________________________________
|Randy Dunlap Intel Corp., DAL Sr. SW Engr.|
|randy.dunlap.at.intel.com 503-696-2055|
|NOTE: Any views presented here are mine alone |
|and may not represent the views of my employer. |
|_________________________________________________|
> -----Original Message-----
> From: David Brownell [mailto:[EMAIL PROTECTED]]
> Sent: Thursday, March 30, 2000 2:55 PM
> To: Dunlap, Randy
> Cc: Richard Henderson; Jeff Garzik; [EMAIL PROTECTED]
> Subject: Re: [linux-usb] Re: alpha and USB
>
>
> That sounds familiar. Was a patch submitted to make OHCI init
> behave better in the face of such major init problems ... like,
> by refusing to initialize?
>
> - Dave
>
>
> "Dunlap, Randy" wrote:
> >
> > Richard and I discussed this some more.
> > We agreed that
> >
> > > > num_ports = readl (&ohci->regs->roothub.a) & 0xff;
> >
> > num_ports in this case is bogus because hc_reset()
> > has already failed with both "USB HC TakeOver failed" and
> > "USB HC reset timed out" messages.
> > In his log file, num_ports was reported as 255, so this
> > readl() was returning at least 0xff, maybe even 0xff...ff.
> >
> > ~Randy
> >
> > > -----Original Message-----
> > > From: David Brownell [mailto:[EMAIL PROTECTED]]
> > >
> > > That could be masking with 0x0f ... the spec says that OHCI may
> > > have from one to fifteen ports, but allocates an extra four bits
> > > in that register. Better, maybe have the driver report an error
> > > if those extra four bits aren't zero (num_ports > 15). Something
> > > clearly is pretty broken if that's ever seen ... as you noticed.
> > >
> > > If the alpha is really looking at the right location for that
> > > register, then whatever OHCI its using has a big problem. I'd
> > > guess that it's got the wrong OHCI register base address.
> >
> >
> ---------------------------------------------------------------------
> > To unsubscribe, e-mail: [EMAIL PROTECTED]
> > For additional commands, e-mail: [EMAIL PROTECTED]
>
---------------------------------------------------------------------
To unsubscribe, e-mail: [EMAIL PROTECTED]