Hi,

Marek Szyprowski <m.szyprow...@samsung.com> writes:

> Calls to USB2 generic PHY calibrate() method has been moved to HCD core,
> which now successfully handles generic PHYs and their calibration after
> every HCD reset. This fixes all the timing issues related to PHY
> calibration done directly from DWC3 driver: incorrect operation after
> system suspend/resume or USB3.0 detection failure when XHCI-plat driver
> compiled as separate module.
>
> Signed-off-by: Marek Szyprowski <m.szyprow...@samsung.com>
> Tested-by: Anand Moon <linux.am...@gmail.com>
> Tested-by: Jochen Sprickerhof <joc...@sprickerhof.de>
> ---
>  drivers/usb/dwc3/core.c | 2 --
>  1 file changed, 2 deletions(-)
>
> diff --git a/drivers/usb/dwc3/core.c b/drivers/usb/dwc3/core.c
> index c9bb93a2c81e..7dd6d419254d 100644
> --- a/drivers/usb/dwc3/core.c
> +++ b/drivers/usb/dwc3/core.c
> @@ -168,7 +168,6 @@ static void __dwc3_set_mode(struct work_struct *work)
>                               otg_set_vbus(dwc->usb2_phy->otg, true);
>                       phy_set_mode(dwc->usb2_generic_phy, PHY_MODE_USB_HOST);
>                       phy_set_mode(dwc->usb3_generic_phy, PHY_MODE_USB_HOST);
> -                     phy_calibrate(dwc->usb2_generic_phy);

are you sure you're the only one using phy_calibrate()? I don't want any
regressions because of this :-p

-- 
balbi

Attachment: signature.asc
Description: PGP signature

Reply via email to