Hi Laurent: I had solved it, because the hardware init work needs 300 milliseconds, i only modified the unicap-devel to get defaults value after waiting 300 milliseconds.
Thank you very much! Best Regards, Tomsun 2011/1/8 Laurent Pinchart <laurent.pinch...@ideasonboard.com> > Hi, > > On Saturday 18 December 2010 08:49:08 tomsun wrote: > > Dear All: > > Now i came across some troubles on new CCD Devices. I can adjust HUE, > > Brightness, Contrast, Saturation and so on, but i can't set default > > parameter which be from firmware by WebCam application. > > the below information comes form uvcvideo driver. > > [snip] > > > uvcvideo: Failed to query (129) UVC control 2 (unit 2) : -110 (exp. 2). > > uvcvideo: Failed to query (129) UVC control 3 (unit 2) : -110 (exp. 2). > > uvcvideo: Failed to query (129) UVC control 6 (unit 2) : -32 (exp. 2). > > Your camera seems to crash when you try to read the current value of the > brightness, contrast and hue controls. Does it happen randomly, or every > time > you try to access those controls ? > > > Does anyone tell me why and how to solve it ? > > -- > Regards, > > Laurent Pinchart > -- Best Regards, tomsun
_______________________________________________ Linux-uvc-devel mailing list Linux-uvc-devel@lists.berlios.de https://lists.berlios.de/mailman/listinfo/linux-uvc-devel