On Fri, Nov 10, 2017 at 08:15:19AM +0200, Kalle Valo wrote:
> Wright Feng <wright.f...@cypress.com> writes:
> 
> > From: Chung-Hsien Hsu <stanley....@cypress.com>
> >
> > The firmware for brcmfmac devices includes information regarding
> > regulatory constraints. For certain devices this information is kept
> > separately in a binary form that needs to be downloaded to the device.
> > This patch adds support to download this so-called CLM blob file. It
> > uses the same naming scheme as the other firmware files with extension
> > of .clm_blob.
> >
> > The CLM blob file is optional. If the file does not exist, the download
> > process will be bypassed. It will not affect the driver loading.
> >
> > Signed-off-by: Chung-Hsien Hsu <stanley....@cypress.com>
> 
> [...]
> 
> > +   err = brcmf_fil_iovar_data_get(ifp, "clmver", buf, sizeof(buf));
> > +   if (err) {
> > +           if (err == -23) {
> 
> No magic numbers, please. Is this supposed to be -ENFILE?

It indicates "Unsupported". I will remove it since it will not affect
the CLM downlaod and driver loading.

Regards,
Chung-Hsien 

> 
> -- 
> Kalle Valo

Reply via email to