On Tue, 19 Dec 2017 10:53:30 +0100
Johannes Berg <[email protected]> wrote:

> > +   if (has_monitor) {
> > +           sdata = rtnl_dereference(local->monitor_sdata);
> > +           if (sdata) {
> > +                   sdata->user_power_level = local->user_power_level;
> > +                   if (txp_type != sdata->vif.bss_conf.txpower_type)
> > +                           update_txp_type = true;
> > +                   sdata->vif.bss_conf.txpower_type = txp_type;
> > +
> > +                   ieee80211_recalc_txpower(sdata, update_txp_type);
> > +           }
> > +   }  
> 
> But do we really need this? I think we can probably live with just not
> having monitor handled here, i.e. only have the "if monitor continue;"
> part?

I don't mind. I just thought, if I call ieee80211_recalc_txpower on the
monitor_sdata interface when called explicitly, I would also do it when
iterating over all interfaces, just to be consistent. I don't know, whether
there are drivers out there, that store power limits on monitor interfaces
separately for injection or whatever.

I can send a patch without the quoted part.

Regards
Peter

Attachment: pgpFmeqlNDAIw.pgp
Description: OpenPGP digital signature