In case there are connected stations, FW needs to disconnect
them before handling PCP stop. This flow can take several
seconds.
Increasing PCP stop timeout to 5 seconds to allow that.

Signed-off-by: Maya Erez <[email protected]>
---
 drivers/net/wireless/ath/wil6210/wmi.c | 4 +++-
 1 file changed, 3 insertions(+), 1 deletion(-)

diff --git a/drivers/net/wireless/ath/wil6210/wmi.c 
b/drivers/net/wireless/ath/wil6210/wmi.c
index c737a79e..19247c5 100644
--- a/drivers/net/wireless/ath/wil6210/wmi.c
+++ b/drivers/net/wireless/ath/wil6210/wmi.c
@@ -41,6 +41,7 @@
 
 #define WIL_WAIT_FOR_SUSPEND_RESUME_COMP 200
 #define WIL_WMI_CALL_GENERAL_TO_MS 100
+#define WIL_WMI_PCP_STOP_TO_MS 5000
 
 /**
  * WMI event receiving - theory of operations
@@ -2195,7 +2196,8 @@ int wmi_pcp_stop(struct wil6210_vif *vif)
                return rc;
 
        return wmi_call(wil, WMI_PCP_STOP_CMDID, vif->mid, NULL, 0,
-                       WMI_PCP_STOPPED_EVENTID, NULL, 0, 20);
+                       WMI_PCP_STOPPED_EVENTID, NULL, 0,
+                       WIL_WMI_PCP_STOP_TO_MS);
 }
 
 int wmi_set_ssid(struct wil6210_vif *vif, u8 ssid_len, const void *ssid)
-- 
1.9.1

Reply via email to