On 8/30/2019 12:41 PM, Johannes Berg wrote:
On Fri, 2019-08-30 at 12:40 +0200, Arend Van Spriel wrote:

+EXPORT_SYMBOL(ieee80211_channel_op_class_to_frequency);

The function ieee80211_operating_class_to_band() uses ranges within
switch statement, eg.:

          case 128 ... 130:
                  *band = NL80211_BAND_5GHZ;
                  return true;

No that you remind me - how is this new function not just a composition
of the existing ones?

i.e. just convert the op_class to band first, and then (band, channel)
to freq?

yup. that would have my preference actually.

Regards,
Arend

Reply via email to