I had a customer with that same problem recently and he applied the latest
TCP/IP Print Session Enhancement PTFS and he hasn't had a recurrance.
V4RxMx TCP/IP PC5250 Printer Session Fixes for OS/400 - Current as of
05/31/2000
The following PTFs are general fixes for configuring PC5250 Printer Session
over TCP/IP protocol:
|---------+--------------+--------------+---------------+----------------|
| |R410 (5769) |R420 (5769) |R430 (5769) |R440(5769) |
|---------+--------------+--------------+---------------+----------------|
|57xxTC1 |SF60365 (1000)|SF60530 (1000)|SF60463 (0077) |SF61175 (0147) |
|---------+--------------+--------------+---------------+----------------|
|57xx999 |MF23706 (1000)|MF23982 (1000)|MF24191 (1000) |MF24192 (0147) |
|---------+--------------+--------------+---------------+----------------|
|57xxSS1 |SF52402 (1000)|SF59303 (1000)|SF62651 (0077) |SF62653 (1000) |
|---------+--------------+--------------+---------------+----------------|
|57xxSS1 | |SF47792 (1000)|SF52102 (9131) | |
|---------+--------------+--------------+---------------+----------------|
|57xxSS1 | |SF48804 (1000)| | |
|---------+--------------+--------------+---------------+----------------|
|57xxSS1 | |SF47400 (8265)| | |
|---------+--------------+--------------+---------------+----------------|
|57xxSS1 | |SF51355 (9068)| | |
|---------+--------------+--------------+---------------+----------------|
Remember to read the cover letters for them. Some have "Enhancements" that
must be performed before/after PTF load.
____________________________________
Kurt Schroeder AS/400 SupportLine Print
phone: T/L 8-456-6177 or 507-286-6177
fax: T/L 8-456-6221 or 507-253-6221
e-mail: [EMAIL PROTECTED]
Scott Klement <[EMAIL PROTECTED]> on 06-13-2000 02:38:54 PM
Please respond to [EMAIL PROTECTED]
To: [EMAIL PROTECTED]
cc:
Subject: (lp5250d) SNA Protocol Error?
I've created a scenario where a document is generated on the AS/400 using
different size fonts, graphics, etc. the print file is set up as an *AFPDS
type, if that matters.
Of course, I'm using Host Print Transform to convert the data to my
printer's language, and lp5250d as a transport to get it to from the
AS/400 to the PC.
Okay, here's the problem...
When I print this document the first time, it works great. But the 2nd
one causes the AS/400 to say that the print writer ended abnormally.
The job log states:
Message . . . . : Error on device PI. Device response code is 6136.
Cause . . . . . : SNA protocol error. There is a probable device
error.
Recovery . . . : Device response codes and their meanings follow:
80040000-Incorrect device address. 20040000-Direction error.
08130000-Bracket bid not supported. 6130-Incorrect data received.
6150-Partial chain received. 6136-Unexpected response received.
6138-System cannot obtain send state. Close the file QPSPLPRT in QSYS
and try the request again. If the error occurs again, enter the ANZPRB
command to run problem analysis.
If I end and restart lp5250d, It does the same thing -- works for the
first spool file, the 2nd one causes it to end with this error again.
I tried the same thing with both LPR/LPD (directly from the AS/400 to
the UNIX box) and with RUMBA under Windows, and did not have any problems,
so its not the document.
Any ideas? Want a tracefile?
-Scott
+---
| This is the LINUX5250 Mailing List!
| To submit a new message, send your mail to [EMAIL PROTECTED]
| To subscribe to this list send email to [EMAIL PROTECTED]
| To unsubscribe from this list send email to [EMAIL PROTECTED]
| Questions should be directed to the list owner/operator:
[EMAIL PROTECTED]
+---
+---
| This is the LINUX5250 Mailing List!
| To submit a new message, send your mail to [EMAIL PROTECTED]
| To subscribe to this list send email to [EMAIL PROTECTED]
| To unsubscribe from this list send email to [EMAIL PROTECTED]
| Questions should be directed to the list owner/operator: [EMAIL PROTECTED]
+---