On Fri, 8 Sep 2000, Scott Klement wrote:
>
> Hi Tom,
>
> I think simply changing:
> outputcommand='scs2ascii | lpr -Pp13'
> to:
> outputcommand=scs2ascii | lpr -Pp13
> will solve your problem.
>
> Since the lp5250d is reading the ~/.tn5250rc file directly, they won't be
> removed automatically by your shell. This means that when it tries to send
> the spooled data to your printer, its treating 'scs2ascii | lpr -Pp13' as
> a single argument, a program name to be run. :) When that fails, lp5250d
> is ending.
>
> If that doesnt work, try writing another message to the list...
Yes, that was the problem. It appears to be working fine now!
Thanks!!
--
Tom Cross Voice: 320-253-1020 FAX: 320-253-6956
System Administrator E-mail: [EMAIL PROTECTED]
Airgas Kendeco Tool Crib http://www.kendeco.com
--> Now with new and improved extension number 207!!! <--
St Cloud Area Linux Users Group: http://www.scalug.org
+---
| This is the LINUX5250 Mailing List!
| To submit a new message, send your mail to [EMAIL PROTECTED]
| To subscribe to this list send email to [EMAIL PROTECTED]
| To unsubscribe from this list send email to [EMAIL PROTECTED]
| Questions should be directed to the list owner/operator: [EMAIL PROTECTED]
+---