On Fri, Jan 25, 2002 at 11:41:24AM +0100, Mihael Knezevic wrote:
> On 2002.01.25 08:41 Scott Klement wrote:
> >
> > Please check the value of your QINACTITV system value.   From the
> > AS/400, type:  DSPSYSVAL SYSVAL(QINACTITV)
> >
> > This system value tells the AS/400 to disconnect users who have been
> > inactive for a certain number of seconds.
> >
> > Good Luck!
> >
> i definitly need that luck, cause the value in QINACTITV is *NONE which
> means there is no checking for not active interactive jobs.
>
> has someone any suggestions?

You can check the parameters INACCTIMO and TIMMRKTIMO with command
CHGTELNA. On my systems (V4R2, V4R3) both values are zero, and tn5250
works without problems.

--