On 26/02/06 09:19 -0800, Abhishek Daga wrote:

<snip>

> Problem:
> I have had issues with routers where frequent reseting is required.
> So to prevent the entire internal network going down because of a bad
> router, I decided to make the connections redundant.
> 
> 
> So connected Port 6 of dlink to port 6 of Dax.
>              Port 7 of dlink to port 6 of smc.
>              Port 7 of dax to port 7 of smc 
> with the assumption that even if the router fails, i'l have
> uninterrupted access.
> 
> But this was not to be. Things got messed up, despite enabled
> connections, machines would not ping each other or the router.
> 
Google: Spanning Tree.
Homework: State with reasons why the original configuration fails.

Devdas Bhagat

-- 
http://mm.glug-bom.org/mailman/listinfo/linuxers

Reply via email to