On Wednesday 01 February 2017 04:30 PM, Anton Blanchard wrote:
Hi Maddy,

+EVENT(PM_INST_DISP,                            0x200f0)
+EVENT(PM_INST_DISP_ALT,                                0x300f0)
Are you sure these are the right events? 0x200f2, 0x300f2 should be
instruction dispatch I think.
Damn. This is bad. I looked at the wrong column. You are right
0x200f2 and 0x300f2 are the PM_INST_DISPL. Nice catch.

Will fix it.

Thanks Anton.
Maddy