Le 08/04/2020 à 04:13, Andrew Donnellan a écrit :
On 7/4/20 9:56 pm, Frederic Barrat wrote:Improve the error message shown if a capi adapter is plugged on a capi-incompatible slot directly under the PHB (no intermediate switch). Fixes: 5632874311db ("cxl: Add support for POWER9 DD2") Cc: [email protected] # 4.14+ Signed-off-by: Frederic Barrat <[email protected]>Seems fine to me, not sure if it needs to go to stable but I suppose this could be causing actual confusion out in the field?
Yes it does. The reason for this patch is it was hit by a customer. Fred
Reviewed-by: Andrew Donnellan <[email protected]>